Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.745
Filtrar
1.
Trends Hear ; 28: 23312165241227815, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38545698

RESUMO

An objective method for assessing speech audibility is essential to evaluate hearing aid benefit in children who are unable to participate in hearing tests. With consonant-vowel syllables, brainstem-dominant responses elicited at the voice fundamental frequency have proven successful for assessing audibility. This study aimed to harness the neural activity elicited by the slow envelope of the same repetitive consonant-vowel syllables to assess audibility. In adults and children with normal hearing and children with hearing loss wearing hearing aids, neural activity elicited by the stimulus /su∫i/ or /sa∫i/ presented at 55-75 dB SPL was analyzed using the temporal response function approach. No-stimulus runs or very low stimulus level (15 dB SPL) were used to simulate inaudible conditions in adults and children with normal hearing. Both groups of children demonstrated higher response amplitudes relative to adults. Detectability (sensitivity; true positive rate) ranged between 80.1 and 100%, and did not vary by group or stimulus level but varied by stimulus, with /sa∫i/ achieving 100% detectability at 65 dB SPL. The average minimum time needed to detect a response ranged between 3.7 and 6.4 min across stimuli and listener groups, with the shortest times recorded for stimulus /sa∫i/ and in children with hearing loss. Specificity was >94.9%. Responses to the slow envelope of non-meaningful consonant-vowel syllables can be used to ascertain audible vs. inaudible speech with sufficient accuracy within clinically feasible test times. Such responses can increase the clinical usefulness of existing objective approaches to evaluate hearing aid benefit.


Assuntos
Surdez , Auxiliares de Audição , Perda Auditiva Neurossensorial , Perda Auditiva , Percepção da Fala , Adulto , Criança , Humanos , Fala , Percepção da Fala/fisiologia , Perda Auditiva/diagnóstico , Perda Auditiva Neurossensorial/reabilitação
2.
Trends Hear ; 28: 23312165231222098, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38549287

RESUMO

This study measured electroencephalographic activity in the alpha band, often associated with task difficulty, to physiologically validate self-reported effort ratings from older hearing-impaired listeners performing the Repeat-Recall Test (RRT)-an integrative multipart assessment of speech-in-noise performance, context use, and auditory working memory. Following a single-blind within-subjects design, 16 older listeners (mean age = 71 years, SD = 13, 9 female) with a moderate-to-severe degree of bilateral sensorineural hearing loss performed the RRT while wearing hearing aids at four fixed signal-to-noise ratios (SNRs) of -5, 0, 5, and 10 dB. Performance and subjective ratings of listening effort were assessed for complementary versions of the RRT materials with high/low availability of semantic context. Listeners were also tested with a version of the RRT that omitted the memory (i.e., recall) component. As expected, results showed alpha power to decrease significantly with increasing SNR from 0 through 10 dB. When tested with high context sentences, alpha was significantly higher in conditions where listeners had to recall the sentence materials compared to conditions where the recall requirement was omitted. When tested with low context sentences, alpha power was relatively high irrespective of the memory component. Within-subjects, alpha power was related to listening effort ratings collected across the different RRT conditions. Overall, these results suggest that the multipart demands of the RRT modulate both neural and behavioral measures of listening effort in directions consistent with the expected/designed difficulty of the RRT conditions.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial , Percepção da Fala , Humanos , Feminino , Idoso , Método Simples-Cego , Perda Auditiva Neurossensorial/terapia , Perda Auditiva Neurossensorial/reabilitação , Ruído/efeitos adversos
3.
Int J Pediatr Otorhinolaryngol ; 179: 111931, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38555811

RESUMO

OBJECTIVE: Asses the efficacy of a Vestibular-balance rehabilitation program to minimize or reverse balance disability in children with sensorineural hearing loss. METHOD: Forty-five hearing-impaired children with balance deficits (i.e., variable degrees of sensorineural hearing loss or auditory neuropathy). Thirty-five were rehabilitated with cochlear implants, and ten with hearing aids. Their age ranged from 4 to 10 years old. A Pre-rehab evaluation was done using questionnaires, neuromuscular evaluation, vestibular and balance office testing, and vestibular lab testing (using cVEMP and caloric test). Customized balances, as well as vestibular rehabilitation exercises, have been applied for three months. That was followed by post-rehab assessment, including the Arabic DHI questionnaire, PBS, BESS, HTT, and DVA test. RESULTS: There was a statistically significant difference in all measured parameters (including the Arabic DHI questionnaire, PBS, BESS, HTT, and DVA test) after rehabilitation. CONCLUSIONS: Vestibular-balance rehabilitation intervention positively impacts vestibular and balance functions in hearing-impaired children.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Potenciais Evocados Miogênicos Vestibulares , Vestíbulo do Labirinto , Criança , Humanos , Pré-Escolar , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/reabilitação , Testes Calóricos
4.
Int J Pediatr Otorhinolaryngol ; 179: 111908, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38461681

RESUMO

OBJECTIVES: The aim of this study is to develop a mobile auditory training application based on gaming for children aged 3-5 years using cochlear implants and to evaluate its usability. METHODS: 4 games were developed in the scope of the application World of Sounds; the crucible sound for auditory awareness, mole hunting for auditory discrimination, find the sound for auditory recognition, and choo-choo for auditory comprehension. The prototype was applied to 20 children with normal hearing and 20 children with cochlear implants, all of whom were aged 3-5. The participants were asked to fill out the Game Evaluation Form for Children. Moreover, 40 parents were included in the study, and the Evaluation Form for the Application was applied. RESULTS: According to the form, at least 80% of children using cochlear implants, and all children in the healthy group, responded well to the usability factors. All factors were obtained as highly useable by parents of the children using cochlear implants. The results indicated that in the healthy group, the usefulness and motivation factors were above moderate, and the other factors were highly useable. In the mole-hunting game, there was no significant difference between the groups in the easy level of the first sub-section (p > 0.05). There was a significant difference between the groups in terms of the other sub-sections of the mole-hunting game and all sub-sections of the crucible sound, find the sound, and the choo-choo games (p < 0.05). While there was no correlation between duration of cochlear implant use and ADSI scores and the third sub-section of the crucible sound game (p > 0.05); a correlation was found in the other sub-sections of crucible sound and all sub-sections of the mole hunting, find the sound, and Choo-Choo games (p < 0.05). CONCLUSION: It is thought that the application World of Sounds can serve as an accessible option to support traditional auditory rehabilitation for children with cochlear implants.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva Neurossensorial , Percepção da Fala , Criança , Humanos , Percepção Auditiva , Perda Auditiva Neurossensorial/reabilitação , Surdez/reabilitação
5.
Sensors (Basel) ; 24(5)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38475083

RESUMO

This paper provides a review of various machine learning approaches that have appeared in the literature aimed at individualizing or personalizing the amplification settings of hearing aids. After stating the limitations associated with the current one-size-fits-all settings of hearing aid prescriptions, a spectrum of studies in engineering and hearing science are discussed. These studies involve making adjustments to prescriptive values in order to enable preferred and individualized settings for a hearing aid user in an audio environment of interest to that user. This review gathers, in one place, a comprehensive collection of works that have been conducted thus far with respect to achieving the personalization or individualization of the amplification function of hearing aids. Furthermore, it underscores the impact that machine learning can have on enabling an improved and personalized hearing experience for hearing aid users. This paper concludes by stating the challenges and future research directions in this area.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial , Humanos , Perda Auditiva Neurossensorial/reabilitação , Aprendizado de Máquina
6.
Ear Hear ; 45(3): 760-774, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38254265

RESUMO

OBJECTIVES: Hearing aid processing in realistic listening environments is difficult to study effectively. Often the environment is unpredictable or unknown, such as in wearable aid trials with subjective report by the wearer. Some laboratory experiments create listening environments to exert tight experimental control, but those environments are often limited by physical space, a small number of sound sources, or room absorptive properties. Simulation techniques bridge this gap by providing greater experimental control over listening environments, effectively bringing aspects of the real-world into the laboratory. This project used simulation to study the effects of wide-dynamic range compression (WDRC) and digital noise reduction (DNR) on speech intelligibility in a reverberant environment with six spatialized competing talkers. The primary objective of this study was to determine the efficacy of WDRC and DNR in a complex listening environment using virtual auditory space techniques. DESIGN: Participants of greatest interest were listeners with hearing impairment. A group of listeners with clinically normal hearing was included to assess the effects of the simulation absent the complex effects of hearing loss. Virtual auditory space techniques were used to simulate a small restaurant listening environment with two different reverberation times (0.8 and 1.8 sec) in a range of signal to noise ratios (SNRs) (-8.5 to 11.5 dB SNR). Six spatialized competing talkers were included to further enhance realism. A hearing aid simulation was used to examine the degree to which speech intelligibility was affected by slow and fast WDRC in conjunction with the presence or absence of DNR. The WDRC and DNR settings were chosen to be reasonable estimates of hearing aids currently available to consumers. RESULTS: A WDRC × DNR × Hearing Status interaction was observed, such that DNR was beneficial for speech intelligibility when combined with fast WDRC speeds, but DNR was detrimental to speech intelligibility when WDRC speeds were slow. The pattern of the WDRC × DNR interaction was observed for both listener groups. Significant main effects of reverberation time and SNR were observed, indicating better performance with lower reverberation times and more positive SNR. CONCLUSIONS: DNR reduced low-amplitude noise before WDRC-amplified the low-intensity portions of the signal, negating one potential downside of fast WDRC and leading to an improvement in speech intelligibility in this simulation. These data suggest that, in some real-world environments that include both reverberation and noise, older listeners with hearing impairment may find speech to be more intelligible if DNR is activated when the hearing aid has fast compression time constants. Additional research is needed to determine the appropriate DNR strength and to confirm results in wearable hearing aids and a wider range of listening environments.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial , Percepção da Fala , Humanos , Perda Auditiva Neurossensorial/reabilitação , Razão Sinal-Ruído , Restaurantes , Ruído
7.
Ear Hear ; 45(1): 142-150, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37434283

RESUMO

OBJECTIVES: This study was designed to examine the effects of hearing aid delay on the neural representation of the temporal envelope. It was hypothesized that the comb-filter effect would disrupt neural phase locking, and that shorter hearing aid delays would minimize this effect. DESIGN: Twenty-one participants, ages 50 years and older, with bilateral mild-to-moderate sensorineural hearing loss were recruited through print advertisements in local senior newspapers. They were fitted with three different sets of hearing aids with average processing delays that ranged from 0.5 to 7 msec. Envelope-following responses (EFRs) were recorded to a 50-msec /da/ syllable presented through a speaker placed 1 meter in front of the participants while they wore the three sets of hearing aids with open tips. Phase-locking factor (PLF) and stimulus-to-response (STR) correlations were calculated from these recordings. RESULTS: Recordings obtained while wearing hearing aids with a 0.5-msec processing delay showed higher PLF and STR correlations compared with those with either 5-msec or 7-msec delays. No differences were noted between recordings of hearing aids with 5-msec and 7-msec delays. The degree of difference between hearing aids was greater for individuals who had milder degrees of hearing loss. CONCLUSIONS: Hearing aid processing delays disrupt phase locking due to mixing of processed and unprocessed sounds in the ear canal when using open domes. Given previous work showing that better phase locking correlates with better speech-in-noise performance, consideration should be given to reducing hearing aid processing delay in the design of hearing aid algorithms.


Assuntos
Surdez , Auxiliares de Audição , Perda Auditiva Neurossensorial , Percepção da Fala , Humanos , Perda Auditiva Neurossensorial/reabilitação , Fala , Ruído , Percepção da Fala/fisiologia
8.
Ear Hear ; 45(1): 151-163, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37553897

RESUMO

OBJECTIVES: This study assessed hearing aid benefits for people with a normal audiogram but hearing-in-noise problems in everyday listening situations. DESIGN: Exploratory double-blinded case-control study whereby participants completed retrospective questionnaires, ecological momentary assessments, speech-in-noise testing, and mental effort testing with and without hearing aids. Twenty-seven adults reporting speech-in-noise problems but normal air conduction pure-tone audiometry took part in the study. They were randomly separated into an experimental group that trialed mild-gain hearing aids with advanced directional processing and a control group fitted with hearing aids with no gain or directionality. RESULTS: Self-reports showed mild-gain hearing aids reduce hearing-in-noise difficulties and provide a better hearing experience (i.e., improved understanding, participation, and mood). Despite the self-reported benefits, the laboratory tests did not reveal a benefit from the mild-gain hearing aids, with no group differences on speech-in-noise tests or mental effort measures. Further, participants found the elevated cost of hearing aids to be a barrier for their adoption. CONCLUSIONS: Hearing aids benefit the listening experience in some listening situations for people with normal audiogram who report hearing difficulties in noise. Decreasing the price of hearing aids may lead to greater accessibility to those seeking remediation for their communication needs.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial , Percepção da Fala , Adulto , Humanos , Audiometria de Tons Puros , Estudos de Casos e Controles , Perda Auditiva Neurossensorial/reabilitação , Estudos Retrospectivos , Método Duplo-Cego
9.
Trends Hear ; 27: 23312165231189596, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37942535

RESUMO

Hearing aid verification with real-ear measurement (REM) is recommended in clinical practice. Improvements, over time, in accuracy of manufacturers' initial fit mean the benefit of routine REM for new adult users is unclear. This registered, double-blinded, randomized, mixed-methods clinical trial aimed to (i) determine whether new adult hearing aid users prefer initial or real-ear fit and (ii) investigate the reasons for preferences. New adult hearing aid users (n = 45) were each fitted with two programs: the initial fit and real-ear fit, both with adjustments based on immediate feedback from the patient. Participants were asked to complete daily paired-comparisons of the two programs with a magnitude estimation of the preference, one for each of clarity/comfort in quiet/noise as well as overall preference. The results revealed gain adjustment requests were low in number and small in magnitude. Deviation from NAL-NL2 targets (after adjustment for a 65 dB SPL input) was close to zero, except at high frequencies where real-ear fits were around 3 dB closer to target. There was no difference in clarity ratings between programs, but comfort ratings favored initial fit. Overall, 10 participants (22%) expressed a preference for real-ear fit. Reasons for preference were primarily based on comfort with the initial fit and clarity with real-ear fit. It may be acceptable to fit new adult users with mild-to-moderate hearing loss without the need for REMs, if the primary outcome of interest is user preference. It remains to be seen if the findings generalize to other fitting software, other outcome measures and more severe hearing loss.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial , Perda Auditiva , Percepção da Fala , Adulto , Humanos , Perda Auditiva/terapia , Perda Auditiva/reabilitação , Perda Auditiva Neurossensorial/reabilitação , Ruído , Método Duplo-Cego
10.
Int J Pediatr Otorhinolaryngol ; 175: 111738, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37847940

RESUMO

OBJECTIVE: Waardenburg syndrome (WS) is a genetic condition associated with moderate to profound sensorineural hearing loss. The aim of this review is to characterize cochlear implant (CI) outcomes in patients with a confirmed clinical diagnosis of WS. DATA SOURCES: MEDLINE, Ovid EMBASE, and Cochrane Library. REVIEW METHODS: All reports describing defined sets of patients with WS who underwent CI and subsequent evaluation of clinical outcomes were included. To harmonize outcome data between studies that used different measures, a binary variable Favored CI was developed to capture success of procedures (1 = favored, 0 = unfavored) based on original authors' description, commentary, discussion, and conclusions. Expert reviewers independently reviewed and selected articles, extracted data and scored Favored CI values. Synthetic and analytic meta-analyses were implemented using standard analytic techniques. RESULTS: Twenty articles meeting inclusion criteria provided data on 192 WS patients and 210 CIs. The mean age at CI was 3.8 years (95% confidence interval [95%CI]; 3.1-4.5 years), and the mean duration of follow up was 5.2 years (95% CI; 3.4-7.0 years). Surgical complications were rare (11/210 implants, 5.2%) where gusher was the most common complication. CIs yielded favorable hearing outcomes in 90% (95% CI; 84-94%) of cases, and appear successful for those with temporal bone anomalies (p = 0.04). CONCLUSIONS: Quantitative synthesis of the study data demonstrates that in the majority of patients with WS, CI yield favorable hearing outcomes and low rates of surgical complications. CI has shown to provide clinical benefits in patients with WS.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Síndrome de Waardenburg , Humanos , Pré-Escolar , Síndrome de Waardenburg/complicações , Síndrome de Waardenburg/cirurgia , Resultado do Tratamento , Perda Auditiva Neurossensorial/cirurgia , Perda Auditiva Neurossensorial/reabilitação
11.
Ear Hear ; 44(6): 1514-1525, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37792897

RESUMO

OBJECTIVES: Hearing aids are an essential and important part of hearing rehabilitation. The combination of technical data on hearing aids and individual rehabilitation needs can give insight into the factors that contribute to the success of rehabilitation. This study sets out to investigate if different subgroups of (comparable) hearing aids lead to differences in the success of rehabilitation, and whether these differences vary between different domains of auditory functioning. DESIGN: This study explored the advantages of including patient-reported outcome measures (PROMs) in the process of purchasing new hearing aids in a large sample of successful hearing aid users. Subject data were obtained from 64 (commercial) hearing aid dispensers and 10 (noncommercial) audiological centers in the Netherlands. The PROM was a 32-item questionnaire and was used to determine the success of rehabilitation using hearing aids by measuring auditory disability over time. The items were mapped on six domains of auditory functioning: detection, discrimination, localization, speech in quiet, speech in noise, and noise tolerance, encompassing a variety of daily-life listening situations. Hearing aids were grouped by means of cluster analysis, resulting in nine subgroups. In total, 1149 subjects were included in this study. A general linear model was used to model the final PROM results. Model results were analyzed via a multifactor Analysis of Variance. Post hoc analyses provided detailed information on model variables. RESULTS: Results showed a strong statistically significant effect of hearing aids on self-perceived auditory functioning in general. Clinically relevant differences were found for auditory domains including detection, speech in quiet, speech in noise, and localization. There was only a small, but significant, effect of the different subgroups of hearing aids on the final PROM results, where no differences were found between the auditory domains. Minor differences were found between results obtained in commercial and noncommercial settings, or between novice and experienced users. Severity of Hearing loss, age, gender, and hearing aid style (i.e., behind-the-ear versus receiver-in-canal type) did not have a clinically relevant effect on the final PROM results. CONCLUSIONS: The use of hearing aids has a large positive effect on self-perceived auditory functioning. There was however no salient effect of the different subgroups of hearing aids on the final PROM results, indicating that technical properties of hearing aids only play a limited role in this respect. This study challenges the belief that premium devices outperform basic ones, highlighting the need for personalized rehabilitation strategies and the importance of evaluating factors contributing to successful rehabilitation for clinical practice.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial , Perda Auditiva , Percepção da Fala , Humanos , Perda Auditiva/reabilitação , Testes Auditivos , Inquéritos e Questionários , Ruído , Perda Auditiva Neurossensorial/reabilitação
12.
Hear Res ; 439: 108893, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37806102

RESUMO

Early assessment of hearing aid benefit is crucial, as the extent to which hearing aids provide audible speech information predicts speech and language outcomes. A growing body of research has proposed neural envelope tracking as an objective measure of speech intelligibility, particularly for individuals unable to provide reliable behavioral feedback. However, its potential for evaluating speech intelligibility and hearing aid benefit in children with hearing loss remains unexplored. In this study, we investigated neural envelope tracking in children with permanent hearing loss through two separate experiments. EEG data were recorded while children listened to age-appropriate stories (Experiment 1) or an animated movie (Experiment 2) under aided and unaided conditions (using personal hearing aids) at multiple stimulus intensities. Neural envelope tracking was evaluated using a linear decoder reconstructing the speech envelope from the EEG in the delta band (0.5-4 Hz). Additionally, we calculated temporal response functions (TRFs) to investigate the spatio-temporal dynamics of the response. In both experiments, neural tracking increased with increasing stimulus intensity, but only in the unaided condition. In the aided condition, neural tracking remained stable across a wide range of intensities, as long as speech intelligibility was maintained. Similarly, TRF amplitudes increased with increasing stimulus intensity in the unaided condition, while in the aided condition significant differences were found in TRF latency rather than TRF amplitude. This suggests that decreasing stimulus intensity does not necessarily impact neural tracking. Furthermore, the use of personal hearing aids significantly enhanced neural envelope tracking, particularly in challenging speech conditions that would be inaudible when unaided. Finally, we found a strong correlation between neural envelope tracking and behaviorally measured speech intelligibility for both narrated stories (Experiment 1) and movie stimuli (Experiment 2). Altogether, these findings indicate that neural envelope tracking could be a valuable tool for predicting speech intelligibility benefits derived from personal hearing aids in hearing-impaired children. Incorporating narrated stories or engaging movies expands the accessibility of these methods even in clinical settings, offering new avenues for using objective speech measures to guide pediatric audiology decision-making.


Assuntos
Surdez , Auxiliares de Audição , Perda Auditiva Neurossensorial , Percepção da Fala , Humanos , Criança , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/reabilitação , Inteligibilidade da Fala , Idioma , Percepção da Fala/fisiologia
13.
Int J Pediatr Otorhinolaryngol ; 170: 111596, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37267660

RESUMO

OBJECTIVES: This study aimed to compare intracochlear electrocochleography (ECochG) findings in a group of cochlear implant (CI) recipients with auditory neuropathy spectrum disorder (ANSD) with a group of CI recipients with sensorineural hearing loss (SNHL). Auditory outcome and spectral resolution findings were also compared among CI recipients with and without cochlear microphonic (CM) responses. METHODS: This single-center, prospective cohort study was undertaken at a tertiary referral center. CM responses by the intracochlear ECochG test were recorded in CI recipients at 0.25-2 kHz. Speech, spatial, and hearing quality (SSQ) outcomes and spectral resolution measured with the spectral-temporally modulated ripple test were obtained for each recipient. The study included 62 implanted ears in 46 recipients, of which 59% (n = 27) were male and 41% (n = 19) were female. Twenty-nine ears with ANSD and 33 ears with SNHL were included. The mean age of the participants was 11 years. The results compared the intracochlear ECochG findings of the ANSD group with those of the SNHL group. RESULTS: Participants were divided into two groups with and without obtainable CM responses. CM responses were obtained in 13 of 29 ears in the ANSD group and 14 of 33 ears in the SNHL group. CM thresholds obtained were better according to behavioral audiometric responses in some frequencies in the ANSD group. No significant difference was found in the auditory outcome and spectral resolution among CI recipients with and without CM responses. CONCLUSIONS: Intracochlear ECochG has a limited potential clinical value for monitoring ANSD. CM thresholds obtained using ECochG may not reflect behavioral hearing thresholds.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Central , Perda Auditiva Neurossensorial , Masculino , Feminino , Humanos , Criança , Audiometria de Resposta Evocada/métodos , Estudos Prospectivos , Perda Auditiva Central/diagnóstico , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/cirurgia , Perda Auditiva Neurossensorial/reabilitação
14.
Otol Neurotol ; 44(7): e492-e496, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37367698

RESUMO

OBJECTIVES: The current study characterizes age and incidence of cochlear implantation among qualifying children with congenital bilateral profound hearing loss in the U.S. STUDY DESIGN: Deidentified cochlear implantation data were acquired from prospectively collected patient registries from two cochlear implant (CI) manufacturers (Cochlear Americas and Advanced Bionics). Children <36 months old were assumed to have congenital bilateral profound sensorineural hearing loss. SETTING: U.S. CI centers. PATIENTS: Children <36 months old who received CIs. INTERVENTIONS: Cochlear implantation. MAIN OUTCOME MEASURES: Age at implantation and incidence. RESULTS: A total of 4,236 children <36 months old underwent cochlear implantation from 2015 to 2019. The median age at implantation was 16 months (interquartile range, 12-24 mo) and did not change significantly during the 5-year study period ( p = 0.09). Patients residing closer to CI centers ( p = 0.03) and treated at higher-volume centers ( p = 0.008) underwent implantation at a younger age. Bilateral simultaneous implantation increased from 38% to 53% of CI surgeries in 2015 and 2019, respectively. Children who received bilateral simultaneous CIs were younger compared with those receiving unilateral or bilateral sequential CIs (median, 14 versus 18 mo; p < 0.001). The incidence of cochlear implantation increased from 7,648 per 100,000 person-years in 2015 to 9,344 in 2019 ( p < 0.001). CONCLUSION: Although the incidence of pediatric CI recipients and the frequency of bilateral simultaneous implantation increased over the study period, age at implantation did not change significantly and far exceeded current Food and Drug Administration (9 mo) and American Academy of Otolaryngology and Head and Neck Surgery position statement (6-12 mo) guidelines.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Percepção da Fala , Criança , Humanos , Pré-Escolar , Implante Coclear/efeitos adversos , Incidência , Perda Auditiva Neurossensorial/epidemiologia , Perda Auditiva Neurossensorial/cirurgia , Perda Auditiva Neurossensorial/reabilitação , Implantes Cocleares/efeitos adversos , Perda Auditiva Bilateral/cirurgia , Resultado do Tratamento
15.
Trends Hear ; 27: 23312165231177509, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37254534

RESUMO

Hearing aid fitting formulas intended for the pediatric population can differ by 6 to 25 dB in prescribed output across frequency leading to large variations in aided audibility. Children perceive these differences and have expressed preferences that favor more audibility for quiet speech and less audibility for noisy speech. In this study, the effect of variations in audibility consistent with hearing aid fittings for children was examined. Sixteen children and adolescents (9-17 years) with mild-to-moderate hearing loss participated. Hearing aids programed to National Acoustic Laboratories or Desired Sensation Level v5.0a targets were fitted to each participant. Also, separate programs with and without a low-level adaptive gain feature were provided with each prescription. Speech reception threshold (SRT) was measured as well as performance for four suprathreshold auditory tasks that increased in cognitive demand. These tasks were word recognition, nonword detection, multiword recall, and rapid word learning. A significant effect of fitting formula, but not low-level or adaptive gain, was observed for SRT. Significant effects of presentation level, fitting formula, and low-level gain were observed for word recognition. The effect of presentation level was significant for nonword detection, multiword recall, and rapid word learning but no other main effects or interactions were significant. Finally, word recognition and nonword detection increased significantly with audibility while multiword recall and word learning did not. The results suggest that audibility assists with the initial perception of auditory input but plays a smaller role in memory formation and learning.


Assuntos
Surdez , Auxiliares de Audição , Perda Auditiva Neurossensorial , Perda Auditiva , Percepção da Fala , Adolescente , Humanos , Criança , Perda Auditiva/diagnóstico , Perda Auditiva/terapia , Inteligibilidade da Fala , Prescrições , Perda Auditiva Neurossensorial/reabilitação
16.
Eur Arch Otorhinolaryngol ; 280(10): 4433-4444, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37043021

RESUMO

PURPOSE: The main objective of this study is to evaluate the short-term and long-term audiological outcomes in patients who underwent cochlear implantation with a robot-assisted system to enable access to the cochlea, and to compare outcomes with a matched control group of patients who underwent cochlear implantation with conventional access to the cochlea. METHODS: In total, 23 patients were implanted by robot-assisted cochlear implant surgery (RACIS). To evaluate the effectiveness of robotic surgery in terms of audiological outcomes, a statistically balanced control group of conventionally implanted patients was created. Minimal outcome measures (MOM), consisting of pure-tone audiometry, speech understanding in quiet and speech understanding in noise were performed pre-operatively and at 3 months, 6 months, 12 months and 2 years post-activation of the audioprocessor. RESULTS: There was no statistically significant difference in pure-tone audiometry, speech perception in quiet and speech perception in noise between robotically implanted and conventionally implanted patients pre-operatively, 3 months, 6 months, 12 months and 2 years post-activation. A significant improvement in pure-tone hearing thresholds, speech understanding in quiet and speech understanding in noise with the cochlear implant has been quantified as of the first measurements at 3 months and this significant improvement remained stable over a time period of 2 years for HEARO implanted patients. CONCLUSION: Clinical outcomes in robot-assisted cochlear implant surgery are comparable to conventional cochlear implantation. CLINICALTRAILS. GOV TRAIL REGISTRATION NUMBERS: NCT03746613 (date of registration: 19/11/2018), NCT04102215 (date of registration: 25/09/2019).


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Perda Auditiva Neurossensorial/cirurgia , Perda Auditiva Neurossensorial/reabilitação
17.
Eur Arch Otorhinolaryngol ; 280(9): 4073-4082, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37099145

RESUMO

OBJECTIVE: To determine tinnitus prevalence and severity in a cohort of unselected first-time cochlear implant (CI) recipients whose primary motive for CI was sensorineural hearing loss (SNHL), and to evaluate the effect of CI on tinnitus after cochlear implantation. METHODS: Prospective longitudinal study of 45 adult CI recipients with moderate to profound SNHL. Patients completed the Danish version of the Tinnitus Handicap Inventory (THI) and a visual analogue scale (VAS) for tinnitus burden before implantation, 4 months after implantation and 14 months after implantation. RESULTS: The study included 45 patients, of which 29 (64%) had pre-implant tinnitus. Median THI score (IQR) significantly decreased from 20 (34) to 12 (24) at first follow-up (p < 0.05) and to 6 points (17) at second follow-up (p < 0.001). Median VAS (IQR) for tinnitus burden decreased from 33 (62) to 17 (40; p = 0.228) and 12 (27, p < 0.05) at the first and second follow-ups, respectively. Tinnitus was totally suppressed in 19% of patients, improved in 48%, remained unchanged in 19% and worsened in 6%. 2 patients reported new tinnitus. At the second follow-up, 74% of patients had slight or no tinnitus handicap, 16% had mild handicaps, 6% had moderate handicaps, and 3% had severe handicaps. High pre-implant THI and VAS scores correlated with greater decrease in THI scores over time. CONCLUSION: 64% of the patients with SNHL had pre-implant tinnitus, which was decreased 4 and 14 months after implantation. Overall, 68% of patients with tinnitus improved their tinnitus handicap after CI. Patients with higher THI and VAS scores had a larger decline and the highest benefits in terms of tinnitus handicap improvement. The study findings demonstrate that the majority of patients with moderate to profound SNHL eligible for cochlear implantation benefit from complete or partial tinnitus suppression and improved quality of life after implantation.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Zumbido , Adulto , Humanos , Estudos Prospectivos , Qualidade de Vida , Estudos Longitudinais , Resultado do Tratamento , Perda Auditiva Neurossensorial/epidemiologia , Perda Auditiva Neurossensorial/cirurgia , Perda Auditiva Neurossensorial/reabilitação , Zumbido/epidemiologia , Zumbido/etiologia
18.
Am J Audiol ; 32(2): 432-439, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37099743

RESUMO

PURPOSE: Consistent hearing device use in young children with hearing loss is challenging for families. A hearing aid accessory, called a pilot cap, is often recommended to families to help mitigate the issues around device retention. Although pilot caps are commonly suggested to families, there is sparse data available about how acoustically transparent they are when used with a hearing aid. The purpose of this study was to measure the acoustic transparency when a hearing aid functions under a pilot cap accessory. METHOD: The Verifit 2 Hearing Aid Analyzer and the Speech Intelligibility Index (SII) were used to measure acoustic transparency related to access of aided speech. Measurements involved four hearing aids that are commonly fit on pediatric patients and four different commercially available pilot caps. SII data were collected at two intensity levels for four simulated sensorineural hearing losses (SNHLs). Response differences between acoustic measurements with a hearing aid plus a pilot cap compared with the hearing aid alone (control) were collected. RESULTS: A total of 80 SII measurements were made. There were 16 SII measurements of the hearing aid alone (control conditions) and 64 SII measurements with combinations of the hearing aids and pilot caps selected for this study. For each hearing aid, there was no significant difference between the SII measurements collected for the hearing aid alone and the hearing aid plus a pilot cap. Additionally, there was no significant difference between the different pilot caps used with each hearing aid tested. CONCLUSIONS: Pilot cap use with the four types of hearing aids in this study results in no significant differences in acoustic transparency compared with the control condition. The data in this study support the use of the pilot caps for hearing device retention in children with hearing loss. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.22647217.


Assuntos
Surdez , Auxiliares de Audição , Perda Auditiva Neurossensorial , Perda Auditiva , Percepção da Fala , Humanos , Criança , Pré-Escolar , Percepção da Fala/fisiologia , Perda Auditiva/reabilitação , Perda Auditiva Neurossensorial/reabilitação
19.
Ear Hear ; 44(5): 1157-1172, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37019441

RESUMO

OBJECTIVES: The cortical auditory evoked potential (CAEP) test is a candidate for supplementing clinical practice for infant hearing aid users and others who are not developmentally ready for behavioral testing. Sensitivity of the test for given sensation levels (SLs) has been reported to some degree, but further data are needed from large numbers of infants within the target age range, including repeat data where CAEPs were not detected initially. This study aims to assess sensitivity, repeatability, acceptability, and feasibility of CAEPs as a clinical measure of aided audibility in infants. DESIGN: One hundred and three infant hearing aid users were recruited from 53 pediatric audiology centers across the UK. Infants underwent aided CAEP testing at age 3 to 7 months to a mid-frequency (MF) and (mid-)high-frequency (HF) synthetic speech stimulus. CAEP testing was repeated within 7 days. When developmentally ready (aged 7-21 months), the infants underwent aided behavioral hearing testing using the same stimuli, to estimate the decibel (dB) SL (i.e., level above threshold) of those stimuli when presented at the CAEP test sessions. Percentage of CAEP detections for different dB SLs are reported using an objective detection method (Hotellings T 2 ). Acceptability was assessed using caregiver interviews and a questionnaire, and feasibility by recording test duration and completion rate. RESULTS: The overall sensitivity for a single CAEP test when the stimuli were ≥0 dB SL (i.e., audible) was 70% for the MF stimulus and 54% for the HF stimulus. After repeat testing, this increased to 84% and 72%, respectively. For SL >10 dB, the respective MF and HF test sensitivities were 80% and 60% for a single test, increasing to 94% and 79% for the two tests combined. Clinical feasibility was demonstrated by an excellent >99% completion rate, and acceptable median test duration of 24 minutes, including preparation time. Caregivers reported overall positive experiences of the test. CONCLUSIONS: By addressing the clinical need to provide data in the target age group at different SLs, we have demonstrated that aided CAEP testing can supplement existing clinical practice when infants with hearing loss are not developmentally ready for traditional behavioral assessment. Repeat testing is valuable to increase test sensitivity. For clinical application, it is important to be aware of CAEP response variability in this age group.


Assuntos
Perda Auditiva Neurossensorial , Percepção da Fala , Criança , Humanos , Lactente , Estimulação Acústica/métodos , Fala , Estudos de Viabilidade , Perda Auditiva Neurossensorial/reabilitação , Potenciais Evocados Auditivos/fisiologia , Percepção da Fala/fisiologia
20.
Am J Audiol ; 32(2): 379-390, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37080240

RESUMO

PURPOSE: This study investigated to what extent residual hearing and rehabilitation options (e.g., hearing aids [HAs]) affect the auditory cortex in children with hearing loss. METHOD: Twenty-one children with bilateral congenital sensorineural hearing loss who were candidates for cochlear implantation were recruited. Voxel-based morphometry analysis was conducted to assess the gray matter (GM) volume in the auditory cortex. Children's residual hearing was measured by pure-tone audiometry at different frequencies. Multiple linear regression models were conducted to examine the effects of residual hearing and the use of HAs on GM volume in the auditory cortex with the control of age and gender. RESULTS: Children with more residual hearing at high frequencies had larger GM volume ratio (corrected by total intracranial volume) in the left Heschl's gyrus (r = -.545, p = .013). An interaction effect between residual hearing and the use of HAs suggested that the effect of residual hearing on GM ratio was moderated by the use of HAs (ß = -.791, p = .020). Compared with children with less residual hearing, children who had more residual hearing benefited more from longer use of HAs in terms of a larger GM ratio. CONCLUSIONS: Our preliminary findings highlight the impact of residual hearing on the neuroanatomy of the auditory cortex in children with hearing loss. Moreover, our results call for more auditory input via HAs for children with more residual hearing to preserve the auditory cortex before cochlear implantation. For children with less residual hearing who might receive limited benefit from HAs, an early cochlear implant would be necessary.


Assuntos
Córtex Auditivo , Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva Neurossensorial , Perda Auditiva , Humanos , Criança , Surdez/reabilitação , Audição , Perda Auditiva Neurossensorial/reabilitação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...